Power transformer for rail technology
Size | P: 15.000VA Ue: 15.000V Ua: 800V frequency: 20.000Hz |
Weight | 12 Kilo empty |
Resonant Transformer 20KW
Technical Data | Rated primary inductance: 300 µH Minimum transformation ratio of 3,3:1:1 Input voltage 370 V Rated input current: 75 A rms Output voltage:: 110 V Frequency: 50 kHz |
Description | The primary side of the transformer works on a series resonant circuit with a frequency of more than 40 kHz (up to a maximum of approx. 60 kHz). In the operating point, this gives a rectangular bipolar voltage waveform with 500 V peak voltage and an almost sinusoidal current form with 75 A rms on the primary side (secondary side scaled in accordance with the transformation ratio). The power to be transmitted is 20 kW for a transformation ratio of 3,3:1:1 (370 V primary to 110 V secondary). |
Trafo
technical Data | frequency: 8kHz, 40kW |
description | potted in heat sink |
transformer
25kW frequency: 8kHz max. losses: 100W diameter: 170mm, high: 125mm | |
description | for high efficiency chargers |