Resonance-converters Buck-Boost-converters

  • High galvanic Separation
  • Smallest designs thanks to latest materials
  • Very good parallelism (agreement) for two primary windings
  • For all topologies…
3-phase transformer

Transformer for battery test systems

Technical Data

3x 4KW, 3×85 Ampere
Secondary voltage: 3 x 48Volt
Frequency: 500 kHz

Resonant Transformer

Resonant Transformer

Technical data

Vin: 20 V – 31 V
Vout: 623 V – 708 V
Imax: 180 A
Pnenn: 3,2 kW
fp: 20 – 70 kHz
Frequency: 50 kHz

Description

The transformer is used in a forced-cooled DC/DC converter full-bridge circuit. Resonant converter 35kHz.
At voltages Vin <24 V, the output power is lowered proportionally to the input voltage.

[Translate to English:] Resonanztrafo

Resonance Transfomer 20KW

Technical data

Rated primary inductance: : 300 µH Minimum
transformation ratio of 3,3:1:1
Input voltage: 370 V
Rated input current: 75 A, rms
Output voltage: 110 V
Frequency: 50 kHz
 

Description

The primary side of the transformer works on a series resonant circuit with a frequency of more than 40 kHz (up to a maximum of approx. 60 kHz). In the operating point, this gives a rectangular bipolar voltage waveform with 500 V peak voltage and an almost sinusoidal current form with 75 A rms on the primary side (secondary side scaled in accordance with the transformation ratio).

The power to be transmitted is 20 kW for a transformation ratio of 3.3:1:1 (370 V primary to 110 V secondary).

Resonance Transfomer

Resonant transformer / choke combination

Technical data

Inductance: 72 µH
I = 36 Arms
Input voltage: 370 V, output voltage: 110 V
Is = 80 A; 63 App
Frequency: 20-25 kHz
Pout =15 kW; U = 5.83:1 (350 /60 V)
 

Description

The two-winding transformer operates on the primary side on a series resonant circuit with a frequency of above 30 kHz (up to a maximum of approx. 60 kHz). This results in a rectangular bipolar voltage shape with 350 V peak voltage and an almost sinusoidal current shape with 50 A effective at the operating point on the primary side (secondary scaled accordingly with transformation ratio).

The power to be transmitted is 15 kW with a transformation ratio of 5.83:1 (350 V primary to 60 V secondary).
The booster choke operates in a step-up converter.

 

EE-power transformer

Designs according to customer requirements

Description

Power transformers in almost all designs.

Ferrite cores: E, EE, ETD, EFD, U, ELP, toroidal core, PM, P, PQ, RM

Arrangement of the power transformers with a wide range of conductors: 0.05 mm to 3 mm as round wire, flat wire, litz wire, triple insulated
 

Outputs

  • 100 VA bis 1MVA
  • 400 Hz bis 1 MHz
  • up to 5.000 A
Forward converter

Converters for solar inverters

Description

forward converter

  • with galvanic separartion
  • With special connections for output winding (PCB)

We are happy to advise you!

We will be happy to answer your questions in a personal meeting. Please contact us.

Data sheet Converters

To use the full functionality, we recommend that you download the document